Diagnosis Procedure
Regarding Wiring Diagram information, refer to "WIRING DIAGRAM ".
- CONNECTOR INSPECTION
- Turn ignition switch OFF.
- Disconnect combination meter and parking brake switch connectors.
- Check connectors and terminals for deformation, disconnection, looseness or damage.
Is the inspection result normal?
YES: GO TO 2
NO: Repair or replace as necessary.
- CHECK PARKING BRAKE SWITCH
Check parking brake switch. Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: GO TO 3.
NO: Replace parking brake switch. Refer to "EXPLODED VIEW ".
- CHECK PARKING BRAKE SWITCH SIGNAL
With CONSULT.
- Connect combination meter connector and parking brake switch connectors.
- Turn ignition switch ON.
- In "DATA MONITOR" select "PARK BRAKE SW" and check parking brake switch signal.
Condition DATA MONITOR Actuate parking brake On Release parking brake Off Is the inspection result normal?
YES: Refer to "WORK FLOW ".
NO: GO TO 4.
- CHECK PARKING BRAKE SWITCH CIRCUIT
- Turn ignition switch OFF.
- Disconnect combination meter and parking brake switch connectors.
- Check continuity between combination meter connector M24 terminal 10 and parking brake switch connector M130 terminal 1.
Combination meter Parking brake switch Continuity Connector Terminal Connector Terminal M24 10 M130 1 Yes - Check continuity between combination meter connector and ground.
Combination meter - Continuity Connector Terminal M24 10 Ground No Is the inspection result normal?
YES: Replace combination meter. Refer to "REMOVAL AND INSTALLATION ".
NO: Repair or replace malfunctioning components.