Diagnosis Procedure
- CHECK COMBINATION METER INPUT SIGNAL
- Start the engine and select METER/M&A on CONSULT.
- Observe OIL W/L DATA MONITOR and the operation of the oil pressure warning lamp on the combination meter.
Component Condition CONSULT Oil pressure warning light Engine running OFF Is the inspection result normal?
YES: Perform ECM self-diagnosis. Refer to "CONSULT FUNCTION ".
NO: Replace combination meter. Refer to "REMOVAL AND INSTALLATION ".