Diagnosis Procedure
Regarding Wiring Diagram information, refer to "WIRING DIAGRAM ".
- CHECK COMBINATION METER INPUT SIGNAL
- Turn ignition switch ON.
- Check voltage between the following terminals of the illumination control switch.
Illumination control switch Ground Condition Voltage (Approx.) Connector Terminals M66 1 When illumination control switch (+) is pressed 0 V Other than the above 5 V 2 When illumination control switch (-) is pressed 0 V Other than the above 5 V Is the inspection result normal?
YES: Inspection End.
NO: GO TO 2.
- CHECK ILLUMINATION CONTROL SWITCH SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect combination meter connector M24 and illumination control switch connector M66.
- Check continuity between combination meter harness connector and illumination control switch harness connector.
Combination meter Illumination control switch Continuity Connector Terminal Connector Terminal M24 33 M66 1 Yes 34 2 - Check continuity between combination meter harness connector and ground.
Combination meter Ground Continuity Connector Terminal M24 33 No 34 Is the inspection result normal?
YES: Check illumination control switch. Refer to "COMPONENT INSPECTION ".
NO: Repair or replace harness or connector.