For MEXICO
- CHECK COMBINATION METER INPUT SIGNAL
Connect CONSULT and check the combination meter input signal. Refer to "COMPONENT FUNCTION CHECK ".
Is the inspection result normal?
YES: GO TO 2.
NO: Replace combination meter.
- CHECK FUEL LEVEL SENSOR SIGNAL CIRCUIT
Check the fuel level sensor signal circuit. Refer to "DIAGNOSIS PROCEDURE ".
Is the inspection result normal?
YES: GO TO 3.
NO: Repair harness or connector.
- CHECK FUEL LEVEL SENSOR UNIT (MAIN)
Perform a unit check for the fuel level sensor unit (main). Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: GO TO 4.
NO: Replace fuel level sensor unit (main). Refer to "REMOVAL AND INSTALLATION ".
- CHECK FUEL LEVEL SENSOR UNIT (SUB)
Perform a unit check for the fuel level sensor unit (sub). Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: GO TO 5.
NO: Replace fuel level sensor unit (sub). Refer to "REMOVAL AND INSTALLATION ".
- CHECK FLOAT INTERFERENCE
Check that the float arm interferes with or binds to other components in the fuel tank.
Is the inspection result normal?
YES: Replace combination meter.
NO: Repair or replace malfunctioning parts.