Diagnosis Procedure
- CHECK A/C AUTO AMP. CONNECTION RECOGNITION SIGNAL
- CHECK A/C AUTO AMP. CONNECTION RECOGNITION SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect combination meter connector and auto amp. connector.
- Check continuity between combination meter harness connector and auto amp. harness connector.
Combination meter Auto amp. Continuity Connector Terminal Connector terminal M34 5 M55 28 Existed - Check continuity between combination meter harness connector and ground.
Combination meter Ground Continuity Connector Terminal M34 5 Not existed Is the inspection result normal?
YES: INSPECTION END