Connecting Rod Bearing (Big End)
- Install the connecting rod cap without the connecting rod bearing installed. After tightening the connecting rod bolt to the specified torque, measure the connecting rod big end inner diameter using an inside micrometer. Refer to "STANDARD AND LIMIT ".