Inspection After Disassembly
WARNING: This page is about a different variant/trim than selected.
Measure the clearance of the oil pump parts.
- Measure clearance with feeler gauge.
- Clearance between outer rotor and oil pump body (position 1).
Standard : 0.114 - 0.179 mm (0.0045 - 0.0070 in)
- Tip clearance between inner rotor and outer rotor (position 2).
Standard : 0.170 - 0.220 mm (0.0067 - 0.0087 in)
- Measure clearance with feeler gauge and straightedge.
- Side clearance between inner rotor and oil pump body (position 3).
Standard : 0.030 - 0.070 mm (0.0012 - 0.0028 in)
- Side clearance between outer rotor and oil pump body (position 4).
Standard : 0.060 - 0.110 mm (0.0024 - 0.0043 in)
- Calculate the clearance between inner rotor and oil pump body as follows:
- Measure the outer diameter of protruded portion of inner rotor (Position 5).
- Measure the inner diameter of oil pump body with inside micrometer (Position 6).
(Clearance) = (Inner diameter of oil pump body) - (Outer diameter of inner rotor).
Standard : 0.035 - 0.070 mm (0.0014 - 0.0028 in)
- Regulator valve clearance:
(Clearance) = D1(Valve hole diameter) - D2 (Outer diameter of valve)
Standard : 0.040 - 0.097 mm (0.0016 - 0.0038 in)
CAUTION: Coat regulator valve with engine oil.
Check that it falls smoothly into the valve hole by its own weight.