Inspection After Removal
WARNING: This page is about a different variant/trim than selected.
- Place a thread so that it is caught in the valve of the water control valve. Immerse fully in a container filled with water. Heat while stirring.
- The valve opening temperature is the temperature at which the water control valve opens and the falls from the thread.
- Continue heating. Check the full-open valve lift amount.NOTE: The full-open valve lift amount standard temperature for the water control valve is the reference value.
- After checking the full-open valve lift amount, lower the water temperature and check the valve closing temperature.VALVE LIFT AMOUNT SPECIFICATIONS
Items Water control valve Valve opening temperature 93.5° - 96.5°C (200° - 206°F) Full-open valve lift amount More than 8 mm/108°C (0.315 in/226°F) Valve closing temperature 90°C (194°F) - If out of the specification, replace water control valve.