COMBINATION METER : Diagnosis Procedure
- CHECK FUSE
Check for blown fuses.
FUSE REFERENCESignal name Fuses No. Battery power supply 9 Ignition signal 3 Is the inspection result normal?
YES: GO TO 2.
NO: Be sure to eliminate cause of malfunction before installing new fuse.
- CHECK POWER SUPPLY CIRCUIT
Check voltage between combination meter harness connector terminal and ground.
IGNITION SWITCH POSITION CHARTTerminals Ignition switch position (+) (-) Combination meter OFF ON Connector Terminal M34 1 Ground Battery voltage Battery voltage 2 Approx. 0 V Battery voltage Is the inspection result normal?
YES: GO TO 3.
NO: Check harness between combination meter and fuse.
- CHECK GROUND CIRCUIT
- Turn ignition switch OFF.
- Disconnect combination meter connector.
- Check continuity between combination meter harness connector terminal and ground.
CONNECTOR TERMINAL CONTINUITY CHART
| Combination meter | Ground | Continuity | |
| Connector | Terminal | ||
| M34 | 3 | Existed | |
| 23 | |||
Is the inspection result normal?
YES: INSPECTION END