Oil Pressure Warning Lamp Stays Off (Ignition Switch ON)
- CHECK OIL PRESSURE WARNING LAMP OPERATION
Activate IPDM E/R auto active test. Refer to "AUTO ACTIVE TEST ".
Does oil pressure warning lamp blink?
YES: GO TO 2.
NO: GO TO 5.
- CHECK IPDM E/R INPUT SIGNAL
- Turn ignition switch ON.
- Check voltage between IPDM E/R harness connector and ground.TERMINAL VOLTAGE REFERENCE
Terminals Condition Voltage (Approx.) (+) (-) IPDM E/R connector Terminal E46 37 Ground Engine stopped 0V Courtesy of NISSAN MOTOR CO., U.S.A.
OK or NG
OK: Replace IPDM E/R. Refer to "REMOVAL AND INSTALLATION OF IPDM E/R ".
NG: GO TO 3.
- CHECK OIL PRESSURE CIRCUIT
- Disconnect IPDM E/R connector and oil pressure switch connector (with MR20DE) or double meter connector (with QR25DE).
- Check continuity between IPDM E/R harness connector E46 (A) terminal 37 and oil pressure switch harness connector F32 (B) terminal 1 (with MR20DE) or double meter connector M89 (C) terminal 6 (with QR25DE).
With MR20DE
37 - 1 : Continuity should exist
Fig 2: Checking Continuity Between IPDM E/R And Oil Pressure Switch Or Double Meter Connector TerminalsCourtesy of NISSAN MOTOR CO., U.S.A.
With QR25DE
37 - 6 : Continuity should exist
OK or NG
OK: With MR20DE, GO TO 4. With QR25DE, refer to "OIL PRESSURE SENSOR INSPECTION ".
NG: Repair harness or connector.
- CHECK OIL PRESSURE SWITCH
Check oil pressure switch. Refer to "COMPONENT INSPECTION ".
OK or NG
OK: Replace IPDM E/R. Refer to "REMOVAL AND INSTALLATION OF IPDM E/R ".
NG: Replace oil pressure switch.
- CHECK CAN COMMUNICATION
Select "METER/M&A" on CONSULT-III, and perform self-diagnosis of combination meter.
Self-diagnostic results content
No malfunction detected: GO TO 6.
Malfunction detected: Check applicable parts, and repair or replace as necessary.
- CHECK COMBINATION METER INPUT SIGNAL
Select "METER/M&A" on CONSULT-III. Operate ignition switch with "OIL W/L" of "DATA MONITOR" and check operation status.
"OIL W/L"
When ignition switch is in ON position (Engine stopped.) : ON
When engine running : OFF
OK or NG
OK: Replace combination meter. Refer to "REMOVAL AND INSTALLATION ".
NG: GO TO 7.
- CHECK BCM INPUT SIGNAL
Select "BCM" on CONSULT-III. Then select "SIGNAL BUFFER". Operate ignition switch with "OIL PRESS SW" of "DATA MONITOR" and check operation status.
"OIL PRESS SW"
When ignition switch is in ON position (Engine stopped.) : ON
When engine running : OFF
OK or NG
OK: Replace BCM. Refer to "REMOVAL AND INSTALLATION OF BCM ".
NG: Replace IPDM E/R. Refer to "REMOVAL AND INSTALLATION OF IPDM E/R ".