Component Inspection
- CHECK METER CONTROL SWITCH
- Turn the ignition switch OFF.
- Disconnect the meter control switch connector.
- Check continuity between the following terminals of the meter control switch.TERMINALS CONTINUITY REFERENCE
Connector Terminal No. Operation and status Continuity M83 1 5 Press the • (select) switch Existed Other than the above Not existed 12 5 Press the □ (enter) switch Existed Other than the above Not existed 11 5 Press the trip reset switch. Existed Other than the above Not existed 4 5 Press the (illumination control) switch Existed Other than the above Not existed 6 5 Press the (illumination control) switch Existed Other than the above Not existed Is inspection result OK?
YES: INSPECTION END
NO: Replace the meter control switch.