Diagnosis Procedure
- CHECK COMBINATION METER INPUT SIGNAL
- Turn ignition switch ON.
- Check voltage between combination meter harness connector terminal and ground.TERMINALS VOLTAGE REFERENCE
Terminals Voltage (Approx.) (+) (-) Combination meter Ground Terminal Connector M34 34 Does it match fuel gauge reading?
YES: GO TO 2.
NO: Replace the combination meter.
- CHECK FUEL LEVEL SENSOR CIRCUIT
- Turn ignition switch OFF.
- Disconnect combination meter connector and fuel level sensor unit (main) connector.
- Check continuity between combination meter harness connector terminal and fuel level sensor unit (main) harness connector terminal.TERMINALS CONTINUITY REFERENCE
Terminals Continuity (+) (-) Combination meter Fuel level sensor unit (main) Connector Terminal Connector Terminal M34 34 B40 2 Existed - Check continuity between combination meter harness connector terminal and ground.TERMINALS CONTINUITY REFERENCE
Terminals Continuity (+) (-) Combination meter Ground Connector Terminal M34 34 Not existed Is the inspection result normal?
YES: GO TO 3.
NO: Repair harness or connector.
- CHECK FUEL LEVEL SENSOR GROUND CIRCUIT
Check continuity between fuel level sensor unit (main) harness connector terminal and combination meter harness connector terminal.
TERMINALS CONTINUITY REFERENCETerminals Continuity (+) (-) Fuel level sensor unit (main) Combination meter Connector Terminal Connector Terminal B40 5 M34 24 Existed Is the inspection result normal?
YES: INSPECTION END
NO: Repair harness or connector.