Heated Oxygen Sensor 2 Heater
WARNING: This page is about a different variant/trim than selected.
- Check resistance between HO2S2 terminals as follows.TERMINALS RESISTANCE CHART
Terminal No. Resistance 2 and 3 3.4 - 4.4 Ω [at 25°C (77°F)] 1 and 2, 3, 4 ∞ Ω (Continuity should not exist) 4 and 1, 2, 3 - If NG, replace heated oxygen sensor 2.CAUTION:
- Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a hard surface such as a concrete floor; use a new one.
- Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor Thread Cleaner tool J-43897-18 or J-43897-12 and approved anti-seize lubricant.