Method of Measurement
WARNING: This page is about a different variant/trim than selected.
- Install the connecting rod bearings to the connecting rod and the cap, and tighten the connecting rod bolts to the specified torque. Using a inside micrometer measure the inner diameter of connecting rod bearing.
(Oil clearance) = (Inner diameter of connecting rod bearing) - (Outer diameter of crankshaft pin)
Standard : 0.035 - 0.045 mm (0.0014 - 0.0018 in)
Limit : 0.10 mm (0.0039 in)
- If clearance cannot be adjusted within the standard, grind crankshaft pin and use undersized bearing. Refer to "HOW TO SELECT A CONNECTING ROD BEARING ".