IPDM E/R Power/Ground Circuit Inspection
- FUSE AND FUSIBLE LINK INSPECTION
Check that the following fusible links or IPDM E/R fuses are not blown.
TERMINALS REFERENCE CHARTTerminal No. Signal name Fuse, fusible link No. 1, 2 Battery power a, b, d OK or NG
OK: GO TO 2.
NG: Replace fuse or fusible link.
- POWER CIRCUIT INSPECTION
- Turn ignition switch OFF.
- Disconnect IPDM E/R harness connector E42.
- Check voltage between IPDM E/R harness connector E42 terminals 1, 2 and ground.
Battery voltage should exist.
OK or NG
OK: GO TO 3.
NG: Repair or replace IPDM E/R power circuit harness.
- GROUND CIRCUIT INSPECTION
- Disconnect IPDM E/R harness connectors E46 and E48.
- Check continuity between IPDM E/R harness connector E46 (A) terminal 39, E48 (B) terminal 59 and ground.
Continuity should exist.
OK or NG
OK: Inspection End.
NG: Repair or replace IPDM E/R ground circuit harness.