How To Alternate Diagnosis Mode

  1. Turn ignition switch to ON and change odo/trip meter to "TRIP A" or "TRIP B".
  2. Turn ignition switch to OFF.
  3. Turn ignition switch to ON when pushing odo/trip meter switch.
  4. Release odo/trip meter switch 1 second after ignition switch is turned ON.
  5. Push odo/trip meter switch three times within 7 seconds.
  6. All odo/trip meter segments should be turned on.
    NOTE: If some segments are not turned on, combination meter should be replaced.
    At this point, the unified meter control unit is turned to diagnosis mode.
    Fig 1: Diagnosis Mode Display
    G04195425Courtesy of NISSAN MOTOR CO., U.S.A.
  7. Push odo/trip meter switch. Indication of each meter/gauge should be as shown in figure while pushing odo/trip meter switch.
    NOTE: It takes a few seconds for indication of fuel gauge and water temperature gauge to become stable.
  8. Turn ignition switch to OFF or start engine to cancel diagnosis mode.
    Fig 2: Pushing Odo/Trip Meter Switch
    G04195426Courtesy of NISSAN MOTOR CO., U.S.A.