How To Alternate Diagnosis Mode
- Turn ignition switch to ON and change odo/trip meter to "TRIP A" or "TRIP B".
- Turn ignition switch to OFF.
- Turn ignition switch to ON when pushing odo/trip meter switch.
- Release odo/trip meter switch 1 second after ignition switch is turned ON.
- Push odo/trip meter switch three times within 7 seconds.
- All odo/trip meter segments should be turned on.NOTE: If some segments are not turned on, combination meter should be replaced.
At this point, the unified meter control unit is turned to diagnosis mode. - Push odo/trip meter switch. Indication of each meter/gauge should be as shown in figure while pushing odo/trip meter switch.NOTE: It takes a few seconds for indication of fuel gauge and water temperature gauge to become stable.
- Turn ignition switch to OFF or start engine to cancel diagnosis mode.