LH Turn
When the turn signal switch is moved to the LH position, power is supplied from turn signal switch terminal 3 to:
- front combination lamp LH terminal 3
- combination meter terminal 35 (with tachometer) or 40 (without tachometer)
- rear combination lamp LH terminal 2.
Ground is supplied to the front combination lamp LH terminal 1 through body grounds E7 and E37.
Ground is supplied to the rear combination lamp LH terminal 4 through body grounds B13 and B19.
Ground is supplied to combination meter terminal 12 (with tachometer) or 39 (without tachometer) through body grounds M28 and M54.
With power and ground supplied, the combination flasher unit controls the flashing of the LH turn signal lamps.