VIAS Control Solenoid Valve

WARNING: This page is about a different variant/trim than selected.

The VIAS control solenoid valve cuts the intake manifold vacuum signal for power valve control. It responds to ON/OFF signals from the ECM. When the solenoid is off, the vacuum signal from the intake manifold is cut. When the ECM sends an ON signal the coil pulls the plunger downward and feeds the vacuum signal to the power valve actuator.

Fig 1: Identifying Power Valve Actuator (2 Of 2)
G02885939Courtesy of NISSAN MOTOR CO., U.S.A.