Foot Position Setting Trimmer: Description
WARNING: This page is about a different car, the 2009 Nissan Maxima. However, it is still accessible from the selected car via links, so may be relevant.
In the FOOT mode, the air blowing to the DEF can be turned ON/OFF.
How to set
Using CONSULT-III, perform "BLOW SET" in "WORK SUPPORT" of HVAC.
WORK SUPPORT ITEMS CHART
| Work support items | Display | DEF door position | |
|---|---|---|---|
| Auto control | Manual control | ||
| BLOW SET | Mode 1 | OPEN | CLOSE |
| Mode 2 (initial status) | OPEN | OPEN | |
| Mode 3 | CLOSE | OPEN | |
| Mode 4 | CLOSE | CLOSE | |
NOTE:
When the battery cable is disconnected from the negative terminal or when the battery voltage becomes 10V or less, the setting of the discharge air mix ratio in FOOT mode may be cancelled.