Test Reading
WARNING: This page is about a different car, the 2009 Nissan Maxima. However, it is still accessible from the selected car via links, so may be relevant.
Recirculating-to-discharge Air Temperature Table
RECIRCULATING-TO-DISCHARGE AIR TEMPERATURE CHART
| Inside air (Recirculating air) at blower assembly inlet | Discharge air temperature at center ventilator °C (°F) | |
|---|---|---|
| Relative humidity % | Air temperature °C (°F) | |
| 50 - 60 | 25 (77) | 10.0 - 12.3 (50 - 54) |
| 30 (86) | 13.2 - 15.3 (56 - 60) | |
| 35 (95) | 17.2 - 21.0 (63 - 70) | |
| 60 - 70 | 25 (77) | 12.3 - 14.9 (54 - 59) |
| 30 (86) | 15.3 - 19.3 (60 - 67) | |
| 35 (95) | 21.0 - 24.4 (70 - 76) | |
Ambient Air Temperature-to-operating Pressure Table
AMBIENT AIR TEMPERATURE-TO-OPERATING PRESSURE CHART
| Ambient air | High-pressure (Discharge side) kPa (kg/cm2 , psi) | Low-pressure (Suction side) kPa (kg/cm2 , psi) | |
|---|---|---|---|
| Relative humidity % | Air temperature °C (°F) | ||
| 50 - 70 | 30 (86) | 1,220 - 1,500 (12.44 - 15.30, 176.9 - 217.5) | 240 - 295 (2.45 - 3.01, 34.8 - 42.8) |
| 35 (95) | 1,360 - 1,690 (13.87 - 17.24, 197.2 - 245.1) | 275 - 335 (2.81 - 3.42, 39.9 - 48.6) | |
| 40 (104) | 1,500 - 1,830 (12.44 - 18.67, 176.9 - 265.4) | 310 - 375 (3.16 - 3.83, 45.0 - 54.4) | |