Pressure Control Solenoid Valve B (Secondary Pressure Solenoid Valve)
WARNING: This page is about a different car, the 2008 Nissan Maxima. However, it is still accessible from the selected car via links, so may be relevant.
- Turn ignition switch OFF.
- Disconnect CVT unit harness connector.
- Check resistance between CVT unit harness connector terminal and ground.PRESSURE CONTROL SOLENOID VALVE B (SECONDARY PRESSURE SOLENOID VALVE)
Solenoid Valve Connector Terminal Resistance (Approx.) Pressure control solenoid valve B (Secondary pressure solenoid valve) F30 3 - Ground 3.0 - 9.0 Ω - If NG, replace the transaxle assembly. Refer to "REMOVAL AND INSTALLATION ".