Turn Signal Lamp Does Not Operate
- CHECK COMBINATION SWITCH INPUT SIGNAL
With CONSULT-II
Select "BCM" on CONSULT-II. With "FLASHER" data monitor, make sure "TURN SIGNAL R" and "TURN SIGNAL L" turns ON-OFF linked with operation of lighting switch.
When lighting switch is in TURN RH position: TURN SIGNAL R ON
When lighting switch is in TURN LH position: TURN SIGNAL L ON
Without CONSULT-II
Refer to "COMBINATION SWITCH INSPECTION ".
OK or NG
OK: GO TO 2.
NG: Check lighting switch. Refer to "COMBINATION SWITCH INSPECTION ".
- ACTIVE TEST
With CONSULT-II
- Select "FLASHER" during active test. Refer to "ACTIVE TEST ".
- Make sure "FLASHER RH" and "FLASHER LH" operate.
Without CONSULT-II
GO TO 3.
OK or NG
OK: Replace BCM. Refer to "BCM ".
NG: GO TO 3.
- CHECK TURN SIGNAL LAMPS CIRCUIT
- Turn ignition switch OFF.
- Disconnect BCM connector and front combination lamp LH and RH connectors.
- Check continuity between BCM connector M19 (A) terminal 60 and front combination lamp LH connector E11 (B) terminal 5.
60 - 5: Continuity should exist.
- Check continuity between BCM connector M19 (A) terminal 61 and front combination lamp RH connector E107 (B) terminal 5.
61 - 5: Continuity should exist.
Fig 3: Checking Continuity Between BCM Connector M19 Terminal 61 And Front Combination Lamp RH Connector E107 Terminal 5OK or NG
OK: GO TO 4.
NG: Repair harness or connector.
- CHECK GROUND
- Check continuity between front combination lamp LH harness connector E11 terminal 10 and ground.
10 - Ground: Continuity should exist.
- Check continuity between front combination lamp RH harness connector E107 terminal 10 and ground.
10 - Ground: Continuity should exist.
OK or NG
OK: GO TO 5.
NG: Repair harness or connector.
- Check continuity between front combination lamp LH harness connector E11 terminal 10 and ground.
- CHECK TURN SIGNAL LAMPS SHORT CIRCUIT
- Disconnect rear combination lamp connectors.
- Check continuity (short circuit) between front combination lamp LH harness connector E11 terminal 5 and ground.
5 - Ground: Continuity should not exist.
- Check continuity (short circuit) between front combination lamp RH harness connector E107 terminal 5 and ground.
5 - Ground: Continuity should not exist.
OK or NG
OK: GO TO 6.
NG: Repair harness or connector.
- CHECK BULB
Check bulb standard of each turn signal lamp is correct. Refer to "EXTERIOR LAMP ".
OK or NG
OK: Replace BCM if turn signal lamp does not work after setting the connector again. Refer to "BCM ".
NG: Replace turn signal lamp bulb. Refer to "FRONT TURN SIGNAL LAMP ".