Front Fog Lamps Do Not Illuminate (Both Sides)
- CHECK COMBINATION SWITCH INPUT SIGNAL
With CONSULT-II
Select "BCM "on CONSULT-II. With "HEAD LAMP "data monitor, make sure "FR FOG SW "turns ON-OFF linked with operation of lighting switch.
When lighting switch is in
: FR FOG SW ON FOG position
Without CONSULT-II
Refer to "COMBINATION SWITCH INSPECTION ".
OK or NG
OK: GO TO 2.
NG: Check lighting switch. Refer to "COMBINATION SWITCH INSPECTION ".
- FOG LAMP ACTIVE TEST
With CONSULT-I I
- Select "IPDM E/R "on CONSULT-II, and select "ACTIVE TEST "on "SELECT DIAG MODE "screen.
- Select "LAMPS "on "SELECT TEST ITEM "screen.
- Touch "FOG "on "ACTIVE TEST "screen.
- Make sure fog lamps operate.
Fog lamp should operate.
Without CONSULT-II
- Start auto active test. Refer to "AUTO ACTIVE TEST ".
- Make sure fog lamps operate.
Fog lamp should operate.
OK or NG
OK: GO TO 3.
NG: GO TO 4.
- CHECK IPDM E/R
- Select "IPDM E/R "on CONSULT-II, and select "DATA MONITOR "on "SELECT DIAG MODE "screen.
- Make sure "FR FOG REQ "turns ON when lighting switch is in FOG position.
When lighting switch is in
: FR FOG REQ ON FOG position
OK or NG
OK: Replace IPDM E/R. Refer to "REMOVAL AND INSTALLATION OF IPDM E/R ".
NG: Replace BCM. Refer to "BCM ".
- CHECK FOG LAMP INPUT SIGNAL
With CONSULT-II
- Turn ignition switch OFF.
- Disconnect front fog lamp RH and LH connectors.
- Turn ignition switch ON.
- Select "IPDM E/R "on CONSULT-II, and select "ACTIVE TEST "on "SELECT DIAG MODE "screen.
- Select "LAMPS "on "SELECT TEST ITEM "screen.
- Touch "FOG "on "ACTIVE TEST "screen.
- When fog lamp is operating, check voltage between front fog lamp RH and LH harness connectors and ground.
Without CONSULT-II
- Turn ignition switch OFF.
- Disconnect front fog lamp RH and LH connectors.
- Start auto active test. Refer to "AUTO ACTIVE TEST ".
- When fog lamp is operating, check voltage between front fog lamp RH and LH harness connectors and ground.FOG LAMP INPUT SIGNAL
Terminals Voltage (+) (-) Front fog lamp connector Terminal RH E102 1 Ground Battery voltage LH E101
OK or NG
OK: GO TO 6.
NG: GO TO 5.
- CHECK FOG LAMP CIRCUIT
- Turn ignition switch OFF.
- Disconnect IPDM E/R connector.
- Check continuity between IPDM E/R connector E124 (A) terminal 36 and front fog lamp RH connector E102 (B) terminal 1.
36 - 1: Continuity should exist.
- Check continuity between IPDM E/R connector E124 (A) terminal 37 and front fog lamp LH connector E101 (B) terminal 1.
37 - 1: Continuity should exist.
Fig 5: Checking Continuity Between IPDM E/R Connector E124 Terminal 37 And Front Fog Lamp LH Connector E101 Terminal 1OK or NG
OK: Replace IPDM E/R. Refer to "REMOVAL AND INSTALLATION OF IPDM E/R ".
NG: Repair harness or connector.
- CHECK FOG LAMP GROUND
- Turn ignition switch OFF.
- Check continuity between front fog lamp RH harness connector E102 terminal 2 and ground.
2 - Ground: Continuity should exist.
- Check continuity between front fog lamp LH harness connector E101 terminal 2 and ground.
2 - Ground: Continuity should exist.
OK or NG
OK: Check front fog lamp bulbs.
NG: Repair harness or connector.