Inspection Flow
- CONFIRM AUTO MODE OPERATION
- Press the AUTO switch.
- Display should indicate AUTO. Confirm that the compressor clutch engages (sound or visual inspection). (Discharge air and blower speed will depend on ambient, in-vehicle and set temperatures.)
OK or NG
OK: GO TO 2.
NG: GO TO 3.
- PERFORM COMPLETE OPERATIONAL CHECK
Perform a complete operational check and check for any symptoms. Refer to "OPERATIONAL CHECK ".
Can a symptom be duplicated?
YES: Refer to "SYMPTOM TABLE ".
NO: System OK.
- CHECK FOR SERVICE BULLETINS
Check for any service bulletins.
Have any service bulletins been issued?
YES: Refer to appropriate service bulletin.
No: GO TO 4.
- PERFORM FRONT AIR CONTROL SELF-DIAGNOSIS
Perform front air control self-diagnosis. Refer to "FRONT AIR CONTROL SELF - DIAGNOSIS ".
OK or NG
OK: GO TO 5.
NG: Perform power and ground circuit for front air control. Refer to "POWER SUPPLY AND GROUND CIRCUIT FOR FRONT AIR CONTROL AND UNIFIED METER AND A/C AMP ".
- CHECK UNIFIED METER AND A/C AMP. POWER AND GROUND CIRCUIT
Check unified meter and A/C amp. main power supply and ground circuit. Refer to "POWER SUPPLY AND GROUND CIRCUIT FOR FRONT AIR CONTROL AND UNIFIED METER AND A/C AMP ".
OK or NG
OK: GO TO 6.
NG: Repair as necessary.
- CHECK AMBIENT SENSOR CIRCUIT (CAUSE CANNOT BE CONFIRMED BY SELF-DIAGNOSIS)
Check ambient sensor circuit. Refer to "AMBIENT SENSOR CIRCUIT ".
OK or NG
OK: GO TO 7.
NG: Repair or replace as necessary.
- CHECK IN-VEHICLE SENSOR CIRCUIT
Check in-vehicle sensor circuit. Refer to "IN-VEHICLE SENSOR CIRCUIT ".
OK or NG
OK: GO TO 8.
NG: Repair or replace as necessary.
- CHECK SUNLOAD SENSOR CIRCUIT
Check sunload sensor circuit. Refer to "SUNLOAD SENSOR CIRCUIT ".
OK or NG
OK: GO TO 9.
NG: Repair or replace as necessary.
- CHECK INTAKE SENSOR CIRCUIT
Check intake sensor circuit. Refer to "INTAKE SENSOR CIRCUIT ".
OK or NG
OK: GO TO 10.
NG: Repair or replace as necessary.
- CHECK AIR MIX DOOR MOTORS PBR CIRCUIT
Check air mix door motors PBR circuit. Refer to "AIR MIX DOOR MOTOR CIRCUIT ".
OK or NG
OK: If the symptom still exists, perform a complete operational check. Refer to "OPERATIONAL CHECK " and check for other symptoms. Refer to "SYMPTOM TABLE ". If no other symptom exists replace unified meter and A/C amp. Refer to "UNIFIED METER AND A/C AMP ".
NG: Repair or replace as necessary.