When performing a refrigerant leak check, use a electronic refrigerant leak detector (J-41995) or equivalent. Ensure that the instrument is calibrated and set properly per the operating instructions.

The electronic refrigerant leak detector (J-41995) is a delicate device. In order to use the electroni refrigerant leak detector (J-41995) properly, read the operating instructions and perform any specified maintenance.

Fig 1: Identifying A/C Electrical Leak Detector (SST)
G04877948Courtesy of NISSAN MOTOR CO., U.S.A.
  1. Position probe approximately 5 mm (3/16 in) away from point to be checked.
    Fig 2: Checking Refrigerant Leak
    G04878150Courtesy of NISSAN MOTOR CO., U.S.A.
  2. When testing, circle each fitting completely with probe.
    Fig 3: Checking Refrigerant Hose
    G04878151Courtesy of NISSAN MOTOR CO., U.S.A.
  3. Move probe along component approximately 25 to 50 mm (1 to 2 in)/sec.
    Fig 4: Identifying Leak Detector Distance