Front Wiper Does Not Operate
- CHECK IPDM E/R TO FRONT WIPERS
With CONSULT-II
- Select "IPDM E/R" with CONSULT-II, and select "ACTIVE TEST" on "SELECT DIAG MODE" screen.
- Select "FRONT WIPER" on "SELECT TEST ITEM" screen.
Without CONSULT-II
- Turn on front wipers using auto active test. Refer to "AUTO ACTIVE TEST ".
- Confirm front wiper operation.
OK or NG
OK: GO TO 4.
NG: GO TO 2.
- IPDM E/R TO FRONT WIPERS CIRCUIT INSPECTION
- Turn ignition switch OFF.
- Disconnect IPDM E/R and front wiper motor.
- Check continuity between IPDM E/R connector terminals and front wiper motor connector terminals.TERMINAL CONTINUITY CHART
IPDM E/R Front wiper motor Continuity Connector Terminals Connector Terminals E121 32 E23 1 Yes 35 4 E122 43 5 - Check continuity between IPDM E/R connector and ground.TERMINAL CONTINUITY CHART
Connector Terminals Continuity E121 32 Ground No 35 E122 43 - Check continuity between IPDM E/R connector terminal and ground.TERMINAL CONTINUITY CHART
Connector Terminals Continuity E122 38 Ground Yes E124 59 - Check continuity between front wiper motor connector and ground.TERMINAL CONTINUITY CHART
Connector Terminal Continuity E23 2 Ground Yes
OK or NG
OK: GO TO 3.
NG: Repair or replace harness.
- IPDM E/R INSPECTION
With CONSULT-II
- Connect IPDM E/R and front wiper motor.
- Select "IPDM E/R" with CONSULT-II, and select "ACTIVE TEST" on "SELECT DIAG MODE" screen.
- Select "FRONT WIPER" on "SELECT TEST ITEM" screen.
Without CONSULT-II
- Connect IPDM E/R and front wiper motor.
- Turn on front wipers using the auto active test. Refer to
"AUTO ACTIVE TEST
".
When front wiper relay, and front wiper high relay are operating, check voltage between IPDM E/R connector and ground.
TERMINAL VOLTAGE CHARTIPDM E/R (-) Condition Voltage (Approx.) (+) Connector Terminal E121 32 Ground Stopped 0 LO operation Battery voltage 35 Stopped 0 HI operation Battery voltage
OK or NG
OK: Replace front wiper motor. Refer to "WIPER MOTOR AND LINKAGE ".
NG: Replace IPDM E/R. Refer to "REMOVAL AND INSTALLATION OF IPDM E/R ".
- COMBINATION SWITCH TO BCM INSPECTION
Select "BCM" on CONSULT-II. With "WIPER" data monitor, check that "FR WIPER INT", "FR WIPER LOW" and "FR WIPER HI" turn ON-OFF according to operation of wiper switch.
OK or NG
OK: GO TO 5.
NG: Check wiper switch. Refer to "COMBINATION SWITCH READING FUNCTION ".
- BCM INSPECTION
Select "BCM" on CONSULT-II. Carry out self-diagnosis of BCM.
Displayed self-diagnosis results
NO DTC: Replace the BCM. Refer to "REMOVAL AND INSTALLATION ".
CAN COMM CIRCUIT: Check CAN communication line of BCM. GO TO "CAN COMMUNICATION INSPECTION USING CONSULT-II (SELF-DIAGNOSIS) ".