Hazard Warning Lamp Does Not Operate But Turn Signal Lamps Operate

WARNING: This page is about a different car, the 2007 Nissan Pathfinder. However, it is still accessible from the selected car via links, so may be relevant.
  1. CHECK BULB 

    Make sure bulb standard of each turn signal lamp is correct. Refer to "EXTERIOR LAMP ".

    OK or NG 

    OK: GO TO 2.

    NG: Replace turn signal lamp bulb. Refer to "FRONT TURN SIGNAL/PARKING LAMP " for front turn signal bulb. Refer to "BULB REPLACEMENT " for rear turn signal bulb.

  2. CHECK HAZARD SWITCH INPUT SIGNAL 

    With CONSULT-II

    Select "BCM" on CONSULT-II. With "FLASHER" data monitor, make sure "HAZARD SW" turns ON-OFF linked with operation of hazard switch.

    Fig 1: Identifying CONSULT II Display - DATA MONITOR
    G04896447

    When hazard switch is in ON position : HAZARD SW ON 

    Without CONSULT-II

    Check voltage between BCM harness connector M18 terminal 29 and ground.

    CONNECTOR TERMINAL VOLTAGE CHART

    BCM (-) Condition Voltage (Approx.)
    (+)
    Connector Terminal
    M18 29 Ground Hazard switch is ON 0V
    Hazard switch is OFF 5V
    Fig 2: Checking Voltage Between BCM Connector M18 Terminal 29 And Ground
    G04896448

    OK or NG 

    OK: Replace BCM. Refer to "REMOVAL AND INSTALLATION ".

    NG: GO TO 3.

  3. CHECK HAZARD SWITCH CIRCUIT 
    1. Turn ignition switch OFF.
    2. Disconnect BCM connector and hazard switch connector.
    3. Check continuity between BCM harness connector M18 terminal 29 and hazard switch harness connector M55 terminal 2.

      29 - 2 : Continuity should exist. 

      Fig 3: Check Continuity Between Connector M18 Terminal 29 And Connector M55 Terminal 2
      G04896449

    OK or NG 

    OK: GO TO 4.

    NG: Repair harness or connector.

  4. CHECK GROUND 

    Check continuity between hazard switch harness connector M55 terminal 1 and ground.

    Fig 4: Checking Continuity Between Connector M55 Terminal 1 And Ground
    G04878672

    1 - Ground : Continuity should exist. 

    OK or NG 

    OK: GO TO 5.

    NG: Repair harness or connector.

  5. CHECK HAZARD SWITCH 
    1. Disconnect hazard switch connector.
    2. Check continuity of hazard switch.
      CONNECTOR TERMINAL CONTINUITY CHART

      Hazard switch Condition Continuity
      Terminal
      2 1 Hazard switch is ON Yes
      Hazard switch is OFF No
      Fig 5: Checking Continuity Hazard Switch Terminals
      G04896451

    OK or NG 

    OK: Replace BCM if hazard warning lamps do not work after setting the connector again. Refer to "REMOVAL AND INSTALLATION ".

    NG: Replace hazard switch. Refer to "REMOVAL AND INSTALLATION ".