Diagnosis Procedure
- CHECK GROUND CONNECTION
- Turn ignition switch OFF.
- Check ground connection E9. Refer to Ground Inspection in "CIRCUIT INSPECTION ".
Is the inspection result normal?
YES: GO TO 2.
NO: Repair or replace ground connection.
- RETIGHTEN A/F SENSOR 1
Loosen and retighten the A/F sensor 1. Refer to "REMOVAL AND INSTALLATION ".
: GO TO 3.
- CHECK FOR INTAKE AIR LEAKAGE
- Start engine and run it at idle.
- Listen for an intake air leakage after the mass air flow sensor.
Is intake air leakage detected?
YES: GO TO 4.
NO: Repair or replace malfunctioning part.
- CLEAR THE MIXTURE RATIO SELF-LEARNING VALUE
- Clear the mixture ratio self-learning value. Refer to "MIXTURE RATIO SELF-LEARNING VALUE CLEAR: SPECIAL REPAIR REQUIREMENT ".
- Run engine for at least 10 minutes at idle speed.
Is the 1st trip DTC P0171, P0172, P0174 or P0175 detected? Is it difficult to start engine?
YES: Perform trouble diagnosis for DTC P0171, P0174 or P0172, P0175. Refer to "DTC LOGIC " or "DTC LOGIC ".
NO: GO TO 5.
- CHECK HARNESS CONNECTOR
- Turn ignition switch OFF.
- Disconnect A/F sensor 1 harness connector.
- Check that water is not inside connectors.
Is the inspection result normal?
YES: GO TO 6.
NO: Repair or replace harness connector.
- CHECK AIR FUEL RATIO (A/F) SENSOR 1 POWER SUPPLY CIRCUIT
- Disconnect A/F sensor 1 harness connector.
- Turn ignition switch ON.
- Check the voltage between A/F sensor 1 harness connector and ground.VOLTAGE SPECIFICATION
DTC A/F sensor Ground Voltage (V) Bank Connector Terminal P2A00 1 F12 4 Ground Battery voltage P2A03 2 F61 4
Is the inspection result normal?
YES: GO TO 8.
NO: GO TO 7.
- DETECT MALFUNCTIONING PART
Check the following.
- IPDM E/R harness connector F10
- 15 A fuse (No. 37)
- Harness for open or short between A/F sensor 1 and fuse
: Repair or replace harness or connectors.
- CHECK A/F SENSOR 1 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between A/F sensor 1 harness connector and ECM harness connector.CONTINUITY CHART
DTC A/F sensor 1 ECM Continuity Bank Connector Terminal Connector Terminal P2A00 1 F12 1 F13 45 Existed 2 49 P2A03 2 F61 1 53 2 57 - Check the continuity between A/F sensor 1 harness connector and ground, or ECM harness connector and ground.CONTINUITY CHART
DTC A/F sensor 1 Ground Continuity Bank Connector Terminal P2A00 1 F12 1 Ground Not existed 2 P2A03 2 F61 1 2 CONTINUITY CHARTDTC ECM Ground Continuity Connector Terminal P2A00 F13 45 Ground Not existed 49 P2A03 53 57 - Also check harness for short to power.
Is the inspection result normal?
YES: GO TO 9.
NO: Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK INTERMITTENT INCIDENT
Perform "INTERMITTENT INCIDENT ".
Is the inspection result normal?
YES: GO TO 10.
NO: Repair or replace malfunctioning part.
- REPLACE AIR FUEL RATIO (A/F) SENSOR 1
Replace malfunctioning air fuel ratio (A/F) sensor 1.
CAUTION:- Discard any A/F sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a hard surface such as a concrete floor; use a new one.
- Before installing new A/F sensor, clean exhaust system threads using Oxygen Sensor Thread Cleaner [commercial service tool (J-43897-18 or J-43897-12)] and approved anti-seize lubricant (commercial service tool).
: INSPECTION END