LEMON Manuals: Even more car manuals for everyone
Home >> Nissan-Datsun >> 2004 >> Altima S, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 1165 (Engine Control System - DTCS P0137 To P0448) >> P0444, P0445 EVAP Canister Purge Volume Control Solenoid Valve >> Diagnosis Procedure

Diagnosis Procedure

WARNING: This page is about a different car, the 2009 Nissan Maxima. However, it is still accessible from the selected car via links, so may be relevant.
  1. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE POWER SUPPLY CIRCUIT
    1. Turn ignition switch OFF.
    2. Disconnect EVAP canister purge volume control solenoid valve harness connector.
    3. Turn ignition switch ON.
    4. Check the voltage between EVAP canister purge volume control solenoid valve harness connector and ground.
    VOLTAGE SPECIFICATION

    EVAP canister purge volume control solenoid valve Ground Voltage
    Connector Terminal
    F29 1 Ground Battery voltage
    Fig 1: Checking Voltage Between EOT Sensor Harness Connector And Ground
    G05869860Courtesy of NISSAN MOTOR CO., U.S.A.

    Is the inspection result normal? 

    YES: GO TO 3.

    NO: GO TO 2.

  2. DETECT MALFUNCTIONING PART

    Check the following.

    • Harness connectors E11, F2
    • Junction block connectors E44, E45
    • Harness for open or short between EVAP canister purge volume control solenoid valve and IPDM E/R
    • Harness for open or short between EVAP canister purge volume control solenoid valve and ECM

    : Repair open circuit, short to ground or short to power in harness or connectors.

  3. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
    1. Turn ignition switch OFF.
    2. Disconnect ECM harness connector.
    3. Check the continuity between EVAP canister purge volume control solenoid valve harness connector and ECM harness connector.
      CONTINUITY CHART

      EVAP canister purge volume control solenoid valve ECM Continuity
      Connector Terminal Connector Terminal
      F29 2 F14 25 Existed
    4. Also check harness for short to ground and short to power.

    Is the inspection result normal? 

    YES-1: With CONSULT-III: GO TO 4.

    YES-2: Without CONSULT-III: GO TO 5.

    NO: Repair open circuit, short to ground or short to power in harness or connectors.

  4. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OPERATION

    With CONSULT-III 

    1. Reconnect all harness connectors disconnected.
    2. Start engine.
    3. Perform "PURG VOL CONT/V" in "ACTIVE TEST" mode with CONSULT-III. Check that engine speed varies according to the valve opening.

    Does engine speed vary according to the valve opening? 

    YES: GO TO 6.

    NO: GO TO 5.

  5. CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE

    Refer to "COMPONENT INSPECTION ".

    Is the inspection result normal? 

    YES: GO TO 6.

    NO: Replace EVAP canister purge volume control solenoid valve.

  6. CHECK INTERMITTENT INCIDENT

    Refer to "INTERMITTENT INCIDENT ".

: INSPECTION END