LEMON Manuals: Even more car manuals for everyone
Home >> Nissan-Datsun >> 2004 >> Altima S, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 1122 (Engine Control System - DTCS U1000 Through P0153) >> DTC P0037, P0038, P0057, P0058 Ho2S2 Heater >> CONSULT-II Reference Value in Data Monitor Mode

CONSULT-II Reference Value in Data Monitor Mode

WARNING: This page is about a different car, the 2007 Nissan Maxima. However, it is still accessible from the selected car via links, so may be relevant.

Specification data are reference values.

CONSULT-II REFERENCE VALUE IN DATA MONITOR MODE

MONITOR ITEM CONDITION SPECIFICATION
HO2S2HTR(B1)
HO2S2 HTR (B2)
  • Engine speed: Below 3, 600 rpm after the following conditions are met.
  • Engine: After warming up
  • Keeping the engine speed between 3, 500 and 4, 000 rpm for 1 minute and at idle for 1 minute under no load
ON
  • Engine speed: Above 3, 600 rpm
OFF