Front Blower Motor Diagnosis Procedure
Regarding Wiring Diagram information, refer to "WIRING DIAGRAM - MANUAL ".
SYMPTOM: Blower motor operation is malfunctioning under starting blower speed control.
- DIAGNOSTIC PROCEDURE
- CHECK FUSES
- Check 15A fuses (Nos. 24 and 27, located in the fuse and fusible link box). Refer to "TERMINAL ARRANGEMENT ".
- Check 10A fuse [No. 8, located in the fuse block (JB)]. Refer to
"TERMINAL ARRANGEMENT
".
Is inspection result normal?
YES: GO TO 3.
NO: GO TO 8.
- CHECK FRONT BLOWER MOTOR POWER SUPPLY
- Turn ignition switch OFF.
- Disconnect front blower motor harness connector.
- Turn ignition switch ON.
- Select any front blower speed except OFF.
- Check voltage between front blower motor harness connector M62 terminal 2 and ground.
2 - Ground: Battery voltage
Courtesy of NISSAN NORTH AMERICA, INC.
Is inspection result normal?
YES: GO TO 12.
NO: GO TO 4.
- CHECK FRONT BLOWER MOTOR RELAY
- Turn Ignition switch OFF.
- Check front blower motor relay. Refer to
"FRONT BLOWER MOTOR COMPONENT INSPECTION ".
Is inspection result normal?
YES: GO TO 5.
NO: Replace front blower motor relay.
- CHECK FRONT BLOWER MOTOR RELAY POWER SUPPLY (SWITCH SIDE)
Check voltage between front blower motor relay harness connector E54 terminals 7 and 5 and ground.
A Condition Voltage (Approx.) (+) Front air control connector Terminal (-) M54 5 Ground Blower motor relay power supply Battery voltage M54 7 Ground Blower motor relay power supply Battery voltage Courtesy of NISSAN NORTH AMERICA, INC.
Is inspection result normal?
YES: GO TO 6.
NO: Repair harness or connector.
- CHECK FRONT BLOWER MOTOR RELAY POWER SUPPLY (COIL SIDE)
- Turn ignition switch ON.
- Check voltage between front blower motor relay harness connector E54 terminal 1 and ground.
A Condition Voltage (Approx.) (+) Front air control connector Terminal (-) M54 1 Ground Blower motor relay power supply (coil side) Battery voltage Courtesy of NISSAN NORTH AMERICA, INC.
Is inspection result normal?
YES: GO TO 7.
NO: Repair or replace harness as necessary.
- CHECK FRONT BLOWER MOTOR POWER FROM RELAY TO FRONT BLOWER MOTOR
- Turn ignition switch OFF.
- Check continuity between front blower motor relay harness connector E54 terminals 6 and 3 and front blower motor harness connector M62 terminal 2.
3, 6 - 2: Continuity should exist .
Courtesy of NISSAN NORTH AMERICA, INC.
Is inspection result normal?
YES: Repair open front blower motor relay ground circuit.
NO: Repair harness or connector between the front blower motor relay and the front blower motor.
- REPLACE FUSE
Refer to "TERMINAL ARRANGEMENT ".
Does fuse No. 24 or 27 open when the front blower motor is turned on?
YES or NO
YES: GO TO 10.
NO: GO TO 9.
- REPLACE FUSE
Refer to "TERMINAL ARRANGEMENT ".
Does fuse No. 8 open when the ignition switch is turned ON?
YES or NO
YES: Repair or replace harness as necessary.
NO: Inspection End.
- CHECK FRONT BLOWER MOTOR POWER SUPPLY CIRCUIT FOR SHORT
- Turn ignition switch OFF.
- Disconnect front blower motor connector.
- Check continuity between front blower motor harness connector M62 terminal 2 and ground.
2 - Ground: Continuity should not exist .
Courtesy of NISSAN NORTH AMERICA, INC.
Is inspection result normal?
YES: GO TO 11.
NO: Repair or replace harness as necessary.
- CHECK FRONT BLOWER MOTOR RELAY (SWITCH SIDE) POWER SUPPLY CIRCUIT FOR SHORT
- Disconnect front blower motor relay connector.
- Check continuity between the front blower motor relay harness connector E54 terminal 7 and terminal 5 and ground.
7, 5 - Ground: Continuity should not exist .
Courtesy of NISSAN NORTH AMERICA, INC.
Is inspection result normal?
YES: Check front blower motor. Refer to "FRONT BLOWER MOTOR DIAGNOSIS PROCEDURE ".
NO: Repair harness or connector.
- CHECK FRONT BLOWER MOTOR
- Turn ignition switch OFF.
- Check front blower motor. Refer to
"FRONT BLOWER MOTOR COMPONENT INSPECTION ".
Is inspection result normal?
YES: GO TO 13.
NO: Replace front blower motor. Refer to "TERMINAL ARRANGEMENT ".
- CHECK FRONT BLOWER MOTOR RESISTOR
Check front blower motor resistor. Refer to "FRONT BLOWER MOTOR COMPONENT INSPECTION ".
Is inspection result normal?
YES: GO TO 14.
NO: Replace front blower motor resistor. Refer to "REMOVAL AND INSTALLATION ".
- CHECK FRONT BLOWER SWITCH
Check front blower switch. Refer to "FRONT BLOWER MOTOR COMPONENT INSPECTION ".
Is inspection result normal?
YES: GO TO 15.
NO: Replace front blower switch. Refer to "REMOVAL AND INSTALLATION ".
- CHECK FRONT BLOWER MOTOR GROUND CIRCUIT TO FRONT BLOWER MOTOR RESISTOR
- Disconnect front blower motor resistor harness connector.
- Check continuity between front blower motor connector M62 (A) terminal 1 and front blower motor resistor harness connector M121 (B) terminal 3.
A B Connector Terminal Connector Terminal Continuity Front blower motor: M62 1 Front blower motor resistor: M121 3 Yes Fig 8: Checking Continuity Between Front Blower Motor Ground Circuit And Front Blower Motor ResistorCourtesy of NISSAN NORTH AMERICA, INC.
Is inspection result normal?
YES: Repair harness or connector between front blower switch connector M51 terminal 8 and ground.
NO: Repair harness or connector between front blower motor resistor and front blower motor.
- CHECK FRONT BLOWER SWITCH
Check front blower switch. Refer to "FRONT BLOWER MOTOR COMPONENT INSPECTION ".
Is inspection result normal?
YES: Repair harness or connector between front blower motor switch connector M51 terminal 8 and front blower motor resistor connector M121 terminal 3.
NO: Replace front blower switch. Refer to "REMOVAL AND INSTALLATION ".