Automatic Door Locks (Unlock Operation)
The automatic door locks (UNLOCK) function is the function that unlocks all doors and fuel lid linked with the key position or shift position. It has 2 types as follows.
IGN OFF Interlock Door Unlock*1
All doors and fuel lid are unlocked when the power supply position is changed from ON to OFF.
BCM outputs the unlock signal to all door lock and fuel lid actuators when it detects that the power supply position is changed from ignition switch ON to OFF.
P Range Interlock Door Unlock
All doors and fuel lid are unlocked when shifting the selector lever from any position other than the P to P position.
BCM outputs the unlock signal to all door lock and fuel lid actuators when it detects that the ignition switch is in the ON position and the shift signal received from TCM via CAN communication is shifted from any position other than the P to P position.
Setting change of Automatic Door Locks (UNLOCK) Function
The UNLOCK operation setting of the automatic door locks function can be changed.
With CONSULT-III
The ON/OFF switching of the automatic door locks (UNLOCK) function and the type selection of the automatic door locks (UNLOCK) function can be performed at the WORK SUPPORT setting of CONSULT-III. Refer to "DOOR LOCK: CONSULT-III FUNCTION (BCM - DOOR LOCK) ".
Without CONSULT-III
The automatic door locks (UNLOCK) function can be switched ON/OFF by performing the following operation.
- Close all doors (door switch OFF)
- Push the ignition switch to the ON position
- Press and hold the door lock and unlock switch for 5 seconds or more in the unlock direction within 20 seconds after turning the power supply position ON.
- The switching is completed when the hazard lamp blinks.
- The ignition switch must be turned OFF and ON again between each setting change.
OFF → ON: 2 blinks
ON → OFF: 1 blink
*1: This function is set to ON before delivery.