Diagnosis Procedure
WARNING: This page is about a different car, the 2009 Nissan Maxima. However, it is still accessible from the selected car via links, so may be relevant.
- CHECK CVT DEVICE POWER SUPPLY
- Turn ignition switch to ACC.
- Disconnect CVT device harness connector.
- Check voltage between CVT device harness connector and ground.VOLTAGE REFERENCE CHART
CVT device (park position switch) Ground Voltage [V] Connector Terminal M78 8 Ground Battery voltage Courtesy of NISSAN MOTOR CO., U.S.A.
Is the inspection result normal?
YES: GO TO 3.
NO: GO TO 2.
- CHECK CVT DEVICE POWER SUPPLY CIRCUIT
- Disconnect BCM harness connector.
- Check continuity between BCM harness connector M19 (A) terminal 84 and CVT device harness connector M78 (B) terminal 8.CONTINUITY REFERENCE CHART
BCM CVT device (park position switch) Continuity Connector Terminal Connector Terminal A: M19 84 B: M78 8 Yes - Check continuity between BCM harness connector M19 (A) terminal 84 and ground.CONTINUITY REFERENCE CHART
BCM Ground Continuity Connector Terminal A: M19 84 Ground No Is the inspection result normal?
YES: Replace BCM. Refer to "REMOVAL AND INSTALLATION ".
NO: Repair harness or connector.
- CHECK CVT DEVICE CIRCUIT (BCM)
- Disconnect BCM harness connector and IPDM E/R harness connector.
- Check continuity between BCM harness connector M19 (A) terminal 87 and CVT device harness connector M78 (B) terminal 9.CONTINUITY REFERENCE CHART
BCM CVT device (park position switch) Continuity Connector Terminal Connector Terminal A: M19 87 B: M78 9 Yes - Check continuity between BCM harness connector M19 (A) terminal 87 and ground.CONTINUITY REFERENCE CHART
BCM Ground Continuity Connector Terminal A: M19 87 Ground No Is the inspection result normal?
YES: GO TO 4.
NO: Repair harness or connector.
- CHECK CVT DEVICE CIRCUIT (IPDM E/R)
- Disconnect BCM harness connector.
- Check continuity between CVT device harness connector M78 (A) terminal 9 and IPDM E/R harness connector E17 (B) terminal 43.CONTINUITY REFERENCE CHART
CVT device (park position switch) IPDM E/R Continuity Connector Terminal Connector Terminal A: M78 9 B: E17 43 Yes - Check continuity between CVT device harness connector M78 (A) terminal 9 and ground.CONTINUITY REFERENCE CHART
CVT device (park position switch) Ground Continuity Connector Terminal A: M78 9 Ground No Is the inspection result normal?
YES: GO TO 5.
NO: Repair harness or connector.
- CHECK CVT DEVICE
Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: GO TO 6.
NO: Replace CVT device. Refer to "REMOVAL AND INSTALLATION ".
- CHECK INTERMITTENT INCIDENT
Refer to "INTERMITTENT INCIDENT ".
Inspection End.