LEMON Manuals: Even more car manuals for everyone
Home >> Nissan-Datsun >> 2004 >> Altima S, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 1026 (Security Control System) >> Component Diagnosis >> B2014 Chain Of STRG-IMMU >> Diagnosis Procedure

Diagnosis Procedure

WARNING: This page is about a different car, the 2009 Nissan Maxima. However, it is still accessible from the selected car via links, so may be relevant.
  1. CHECK STEERING LOCK UNIT POWER SUPPLY
    1. Turn ignition switch OFF.
    2. Disconnect steering lock unit harness connector.
    3. Check voltage between steering lock unit harness connector and ground while turning ignition switch from OFF to ACC.
      VOLTAGE REFERENCE CHART

      Steering lock unit Ground Ignition switch position Voltage [V]
      Connector Terminal
      M32 7 Ground OFF → ACC Battery voltage
      OFF or ON 0
      Fig 1: Checking Voltage Between Steering Lock Unit Harness Connector And Ground
      G05876349Courtesy of NISSAN MOTOR CO., U.S.A.

      Is the inspection result normal? 

      YES: GO TO  3

      NO: GO TO 2

  2. CHECK STEERING LOCK UNIT POWER SUPPLY CIRCUIT
    1. Turn ignition switch OFF.
    2. Disconnect BCM harness connector.
    3. Check continuity between steering lock unit harness connector M32 (A) terminal 7 and BCM harness connector M19 (B) terminal 94.
      CONTINUITY REFERENCE CHART

      Steering lock unit BCM Continuity
      Connector Terminal connector Terminal
      A: M32 7 B: M19 94 Yes
    4. Check continuity between steering lock unit harness connector M32 (A) terminal 7 and ground.
      Fig 2: Checking Continuity Between Steering Lock Unit Harness Connector M32 Terminal 7 And Ground
      G05876350Courtesy of NISSAN MOTOR CO., U.S.A.
      CONTINUITY REFERENCE CHART

      Steering lock unit Ground Continuity
      Connector Terminal
      A: M32 7 Ground No

      Is the inspection result normal? 

      YES: GO TO  6

      NO: Repair harness or connector.

  3. CHECK STEERING LOCK UNIT GROUND CIRCUIT
    1. Turn ignition switch OFF.
    2. Check continuity between steering lock unit and ground.
      CONTINUITY REFERENCE CHART

      Steering lock unit Ground Continuity
      Connector Terminal
      M32 5 Ground Yes
      6
      Fig 3: Checking Continuity Between Steering Lock Unit And Ground
      G05876351Courtesy of NISSAN MOTOR CO., U.S.A.

      Is the inspection result normal? 

      YES: GO TO 4

      NO: Repair harness or connector.

  4. CHECK STEERING LOCK UNIT COMMUNICATION SIGNAL
    1. Connect steering lock unit harness connector.
    2. Using an oscilloscope, read voltage signal between steering lock unit harness connector and ground.
      Fig 4: Checking Read Voltage Signal Between Steering Lock Unit Harness Connector And Ground
      G05876352Courtesy of NISSAN MOTOR CO., U.S.A.
      VOLTAGE REFERENCE CHART

      Steering lock unit Ground Steering lock unit condition Value
      Connector Terminal
      M32 2 Ground Lock Battery voltage
      Lock or unlock
      G05876353Courtesy of NISSAN MOTOR CO., U.S.A.
      For 15 seconds after unlock Battery voltage
      15 seconds or later after unlock. 0 V

      Steering is locked: Opening the door when ignition switch is ON to OFF. 

      Steering is unlocked: Ignition switch is OFF to ACC. 

      Is the inspection result normal? 

      YES: Replace steering lock unit.

      NO: GO TO 5

  5. CHECK STEERING LOCK UNIT COMMUNICATION CIRCUIT
    1. Turn ignition switch OFF.
    2. Disconnect BCM harness connector.
    3. Check continuity between BCM harness connector M19 (A) terminal 99 and steering lock unit harness connector M32 (B) terminal 2.
      CONTINUITY REFERENCE CHART

      BCM Steering lock unit Continuity
      Connector Terminal connector Terminal
      A: M19 99 B: M32 2 Yes
    4. Check continuity between BCM harness connector M19 (A) terminal 99 and ground.
      Fig 5: Checking Continuity Between BCM Harness Connector M19 Terminal 99 And Ground
      G05876354Courtesy of NISSAN MOTOR CO., U.S.A.
      CONTINUITY REFERENCE CHART

      BCM Ground Continuity
      Connector Terminal
      A: M19 99 Ground No

      Is the inspection normal? 

      YES: GO TO 6

      NO: Repair harness or connector.

  6. CHECK INTERMITTENT INCIDENT

    Refer to "INTERMITTENT INCIDENT ".

    Inspection End.