LEMON Manuals: Even more car manuals for everyone
Home >> Nissan-Datsun >> 2004 >> Altima S, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 1014 (Meter, Warning Lamp & Indicator) >> Component Diagnosis >> Power Supply And Ground Circuit >> Combination Meter >> COMBINATION METER: Diagnosis Procedure

COMBINATION METER: Diagnosis Procedure

WARNING: This page is about a different car, the 2009 Nissan Maxima. However, it is still accessible from the selected car via links, so may be relevant.
  1. CHECK FUSES

    Check for blown combination meter fuses.

    FUSES REFERENCE

    Unit Power source Fuse No.
    Combination meter Battery 11
    Ignition switch ON or START 4

    Is the inspection result normal? 

    YES: GO TO 2

    NO: If fuse is blown, be sure to eliminate cause of malfunction before installing new fuse.

  2. POWER SUPPLY CIRCUIT CHECK
    1. Disconnect combination meter connector.
    2. Check voltage between combination meter harness connector M24 terminals 1, 2, and ground.
    TERMINALS VOLTAGE REFERENCE

    Terminals Ignition switch position
    (+) (-) OFF ON START
    Connector Terminal
    M24 1 Ground Battery voltage Battery voltage Battery voltage
    2 0V Battery voltage Battery voltage
    Fig 1: Checking Voltage Between Combination Meter Harness Connector M24 Terminals 1, 2, And Ground
    G05879166Courtesy of NISSAN MOTOR CO., U.S.A.

    Is the inspection result normal? 

    YES: GO TO 3

    NO: Check harness for open between combination meter and fuse.

  3. GROUND CIRCUIT CHECK
  1. Turn ignition switch OFF.
  2. Check continuity between combination meter harness connector terminals 3, 4, 23 and ground.
TERMINALS CONTINUITY REFERENCE

Terminals Continuity
(+) (-)
Connector Terminal
M24 3 Ground Yes
4
23
Fig 2: Checking Continuity Between Combination Meter Harness Connector Terminals 3, 4, 23 And Ground
G05879167Courtesy of NISSAN MOTOR CO., U.S.A.

Is the inspection result normal? 

YES: Inspection End.

NO: Check ground harness.