DTC P1147 Or DTC P1167: Description
HO2S2, located after 3-way catalyst, monitors the oxygen level in the exhaust gas. Even if switching characteristics of HO2S1 are shifted, the air fuel ratio is controlled to stoichiometric, by the signal from HO2S2. This sensor is made of ceramic zirconia. The zirconia generates voltage from about one volt in richer conditions to zero volts in leaner conditions. Under normal conditions, HO2S2 is not used for engine control.
HO2S2 has a much longer switching time between rich and lean than HO2S1. The oxygen storage capacity before the 3-way catalyst causes the longer switching time. To judge the malfunctions of HO2S2, ECM monitors whether the maximum voltage of sensor is sufficiently high during the various driving condition such as fuel-cut.