Home >> Nissan-Datsun >> 2003 >> Sentra Limited >> Repair and Diagnosis >> External Pages >> Different car >> Section 2388 (Engine Control System - DTCS U1000 To P0159) >> DTC P0138, P0158 Ho2S2 >> Component Inspection >> Heated Oxygen Sensor 2 >> With CONSULT-II

With CONSULT-II

WARNING: This page is about a different car, the 2007 Nissan Pathfinder. However, it is still accessible from the selected car via links, so may be relevant.
  1. Turn ignition switch ON and select "DATA MONITOR" mode with CONSULT-II.
    Fig 1: Identifying CONSULT-II Display - DATA MONITOR
    G04900167Courtesy of NISSAN NORTH AMERICA, INC.
  2. Start engine and warm it up to the normal operating temperature.
  3. Turn ignition switch OFF and wait at least 10 seconds.
  4. Start engine and keep the engine speed between 3, 500 and 4, 000 rpm for at least 1 minute under no load.
  5. Let engine idle for 1 minute.
  6. Select "FUEL INJECTION" in "ACTIVE TEST" mode, and select "HO2S2 (B1)/(B2)" as the monitor item with CONSULT-II.
    Fig 2: Identifying CONSULT-II Display - ACTIVE TEST
    G04900304Courtesy of NISSAN NORTH AMERICA, INC.
  7. Check "HO2S2 (B1)/(B2)" at idle speed when adjusting "FUEL INJECTION" to ±25%.
    Fig 3: Identifying Fuel Injection Idle Speed Graph
    G04895574Courtesy of NISSAN NORTH AMERICA, INC.

    "HO2S2 (B1)/(B2)" should be above 0.68V at least once when the "FUEL INJECTION" is +25%. 

    "HO2S2 (B1)/(B2)" should be below 0.18V at least once when the "FUEL INJECTION" is -25%. 

    CAUTION:
    • Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a hard surface such as a concrete floor; use a new one.
    • Before installing new oxygen sensor, clean exhaust system threads (using Oxygen Sensor Thread Cleaner tool J-43897-18 or J-43897-12) and approved anti-seize lubricant.