LEMON Manuals: Even more car manuals for everyone
Home >> Nissan-Datsun >> 2003 >> Sentra Limited >> Repair and Diagnosis >> External Pages >> Different car >> Section 2387 (Engine Control System - Introduction) >> On Board Diagnostic (OBD) System >> Emission-related Diagnostic Information >> Test Value And Test Limit (GST Only - Not Applicable To Consult-II)

Test Value And Test Limit (GST Only - Not Applicable To Consult-II)

WARNING: This page is about a different car, the 2007 Nissan Pathfinder. However, it is still accessible from the selected car via links, so may be relevant.

The following is the information specified in Service $06 of SAE J1979.

The test value is a parameter used to determine whether a system/circuit diagnostic test is OK or NG while being monitored by the ECM during self-diagnosis. The test limit is a reference value which is specified as the maximum or minimum value and is compared with the test value being monitored.

These data (test value and test limit) are specified by Test ID (TID) and Component ID (CID) and can be displayed on the GST screen.

TEST VALUE AND TEST LIMIT

Item Self-diagnostic test item DTC Test value (GST display) Test limit Conversion
TID CID
CATALYST Three way catalyst function (Bank 1) P0420 01H 01H Max. 1/128
P0420 02H 81H Min. 1
Three way catalyst function (Bank 2) P0430 03H 02H Max. 1/128
P0430 04H 82H Min. 1
EVAP SYSTEM EVAP control system (Small leak) P0442 05H 03H Max. 1/128mm2
EVAP control system purge flow monitoring P0441 06H 83H Min. 20mV
EVAP control system (Very small leak) P0456 07H 03H Max. 1/128mm2
HO2S Air fuel ratio (A/F) sensor 1 (Bank 1) P0131 41H 8EH Min. 5 mV
P0132 42H 0EH Max. 5 mV
P2A00 43H 0EH Max. 0.002
P0133 45H 8EH Min. 0.004
P0130 46H 0EH Max. 5 mV
P0130 46H 0EH Max. 5 mV
P0133 48H 8EH Min. 0.004
Air fuel ratio (A/F) sensor 1 (Bank 2) P0151 4CH 8FH Min. 5 mV
P0152 4DH 0FH Max. 5 mV
P2A03 4EH 0FH Max. 0.002
P0153 50H 8FH Min. 0.004
P0150 51H 0FH Max. 5 mV
P0150 51H 0FH Max. 5 mV
P0153 53H 8FH Min. 0.004
Heated oxygen sensor 2 (Bank 1) P0139 19H 86H Min. 10mV/500ms
P0137 1AH 86H Min. 10mV
P1146 1BH 06H Max. 10mV
P0138 1CH 06H Max. 10mV
Heated oxygen sensor 2 (Bank 2) P0159 21H 87H Min. 10mV/500ms
P0157 22H 87H Min. 10mV
P0158 24H 07H Max. 10mV
HO2S HEATER Air fuel ratio (A/F) sensor 1 heater (Bank 1) P0032 57H 10H Max. 5 mV
P0031 58H 90H Min. 5 mV
Air fuel ratio (A/F) sensor 1 heater (Bank 2) P0052 59H 11H Max. 5 mV
P0051 5AH 91H Min. 5 mV
Heated oxygen sensor 2 heater (Bank 1) P0038 2DH 0AH Max. 20mV
P0037 2EH 8AH Min. 20mV
Heated oxygen sensor 2 heater (Bank 2) P0058 2FH 0BH Max. 20mV
P0057 30H 8BH Min. 20mV