LEMON Manuals: Even more car manuals for everyone
Home >> Nissan-Datsun >> 2003 >> Sentra Limited >> Repair and Diagnosis >> External Pages >> Different car >> Section 2021 (Starting & Charging System) >> Generator >> Trouble Diagnoses with Battery/Starting/Charging System Tester >> Diagnostic Procedure 1 >> Check Charge Warning Lamp Circuit (Open)

Check Charge Warning Lamp Circuit (Open)

WARNING: This page is about a different car, the 2007 Nissan Pathfinder. However, it is still accessible from the selected car via links, so may be relevant.
  1. CHECK CHARGE WARNING LAMP CIRCUIT CONNECTION 
    1. Turn the ignition switch OFF.
    2. Check terminal "2" harness connector.

    OK or NG 

    OK: GO TO 2.

    NG: Repair terminal "2" connection. Confirm repair by performing complete Battery/Starting/Charging system test. Refer to "TROUBLE DIAGNOSES WITH BATTERY/STARTING/CHARGING SYSTEM TESTER ".

  2. CHECK CHARGE WARNING LAMP CIRCUIT (OPEN) 
    1. Disconnect E205 connector from generator.
    2. Apply ground to connector E205 terminal 2 with the ignition switch in the ON position.

      CHARGE lamp should light up. 

      Fig 1: Applying Ground To Connector E205 Terminal 2
      G04903574

    OK or NG 

    OK: GO TO "WORK FLOW ".

    NG: Check the following.

    • Charge warning lamp (Combination meter)
    • Harness for open or short between combination meter and fuse
    • Harness for open between combination meter and generator