BATTERY ELECTROLYTE TEMPERATURE - ADD TO SPECIFIC GRAVITY READING TABLE

Battery electrolyte temperature °C (°F) Add to specific gravity reading
71(160) 0.032
66(150) 0.028
60(140) 0.024
54(130) 0.020
49(120) 0.016
43(110) 0.012
38(100) 0.008
32(90) 0.004
27(80) 0
21(70) -0.004
16(60) -0.008
10(50) -0.012
4(40) -0.016
-1 (30) -0.020
-7 (20) -0.024
-12(10) -0.028
-18(0) -0.032
CORRECTED SPECIFIC GRAVITY - APPROXIMATE CHARGE CONDITION TABLE

Corrected specific gravity Approximate charge condition
1.260 -1.280 Fully charged
1.230-1.250 3/4 charged
1.200 - 1.220 1/2 charged
1.170 - 1.190 1/4 charged
1.140-1.160 Almost discharged
1.110-1.130 Completely discharged