LEMON Manuals: Even more car manuals for everyone
Home >> Nissan-Datsun >> 2003 >> Sentra Limited >> Repair and Diagnosis >> External Pages >> Different car >> Section 1165 (Engine Control System - Qr25DE) >> On Board Refueling Vapor Recovery (ORVR) >> Component Inspection >> Refueling EVAP Vapor Cut Valve >> With GST

With GST

WARNING: This page is about a different car, the 2004 Nissan Sentra. However, it is still accessible from the selected car via links, so may be relevant.
  1. Remove fuel tank. Refer to "FUEL TANK ".
  2. Drain fuel from the tank as follows:
    • Remove fuel level sensor unit retainer.
    • Drain fuel from the tank using a handy pump into a fuel container.
  3. Check refueling EVAP vapor cut valve for being stuck closed as follows.

    Blow air into the refueling EVAP vapor cut valve (from hose end B  ), and check that the air flows freely into the tank.

  4. Check EVAP vapor cut valve for being stuck open as follows.
    • Connect vacuum pump to hose ends A  and B  using a suitable 3-way connector.
    • Remove fuel level sensor unit retainer with fuel level sensor unit.

      Always replace O-ring with new one. 

    • Put fuel tank upside down.
    • Apply vacuum pressure to both hose ends A  and B  [-13.3 kPa (-100 mmHg, -3.94 inHg)] with fuel level sensor unit retainer remaining open and check that the pressure is applicable.
      Fig 1: Refueling EVAP Vapor Cut Valve
      G00778418Courtesy of NISSAN MOTOR CO., U.S.A.