Turn Signal Lamp Does Not Operate
- CHECK BULB
Check bulb standard of each turn signal lamp is correct.
OK or NG
- OK : GO TO 2.
- NG : Replace turn signal lamp bulb.
- COMBINATION SWITCH CIRCUIT CHECK
Select BCM on CONSULT-II. Carry out "BCM C/U" self-diagnosis.
Displayed results of self-diagnosis
Diagnosis system 1 - 5: Combination switch system malfunction.
No malfunction detected: GO TO 3.
- COMBINATION SWITCH INPUT SIGNAL CHECK
Select "BCM" on CONSULT-II. With "FLASHER" data monitor, check that "TURN SIGNAL R" and "TURN SIGNAL L" turn ON-OFF linked with operation of turn signal switch.
- When turn signal switch LH position :TURN SIGNAL L ON
- When turn signal switch RH position :TURN SIGNAL R ON
OK or NG
- OK : GO TO 4.
- NG : Replace lighting switch.
- ACTIVE TEST
- Select "BCM" on CONSULT-II. Select "FLASHER" active test.
- Check that "FLASHER RIGHT" and "FLASHER LEFT" operate.
- Turn signal lamp: Should turn ON
OK or NG
- OK : Replace BCM.
- NG : GO TO 5.
- SHORT CIRCUIT CHECK
- Turn ignition switch OFF.
- Disconnect BCM connector and all turn signal lamp connectors.
- Check continuity (short circuit) between BCM harness connector M1 terminal 21(PU/W) and ground.
- Continuity not should exist
- Check continuity (short circuit) between BCM harness connector M1 terminal 22(G/W) and ground.
- Continuity not should exist
OK or NG
- OK : Replace BCM.
- NG : After repairing harness be sure to disconnect battery negative cable, and then reconnect it.