LEMON Manuals: Even more car manuals for everyone
Home >> Nissan-Datsun >> 1990 >> Sentra Base >> Repair and Diagnosis >> Electrical >> Gauges >> Instrument Panel - Standard >> Testing >> Testing Temperature Sending Unit

Testing Temperature Sending Unit

Check resistance between temperature sending unit terminals and body ground. At 140°F (60°C) resistance should be 70-90 ohms and at 212°F (100°C) resistance should be 21-24 ohms.

Fig 1: Rear Views of Combination Meters (W/ Tachometer)
G91D02345Courtesy of NISSAN MOTOR CO., U.S.A.
Fig 2: Rear Views of Combination Meters (W/O Tachometer)
G90C09394Courtesy of NISSAN MOTOR CO., U.S.A.