Float Level
With air horn removed and inverted, raise float and lower it slowly until it just touches needle valve. Measure distance between float and air horn gasket surface (gasket removed). See Fig 1. Bend tang to adjust to specifications. See appropriate CARBURETOR ADJUSTMENT SPECIFICATIONS table in this article.