Home >> Mitsubishi >> 2018 >> Outlander Sport LE, FWD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 8 (Electronic Control (AWD)) >> On-Vehicle Service >> Check Of Electronic Control Coupling >> Resistance Measurement Between Electronic Control Coupling Solenoid Connector Terminals

Resistance Measurement Between Electronic Control Coupling Solenoid Connector Terminals

WARNING: This page is about a different variant/trim than selected.

Disconnect the D-23 connector, and measure the resistance value between the connector terminals on the electronic control coupling side. If the measured resistance value is out of the standard value range, replace the electronic control coupling (Refer to DRIVE MODE SELECTOR  ).

Standard value: 2.2 - 4.0 Ω 

Fig 1: Measuring Resistance Value Between Connector Terminals On Electronic Control Coupling Side
G09670223Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.