Removal And Installation
WARNING:
Do not disconnect the negative terminal of auxiliary battery for 1 minute after turning the electric motor switch to LOCK (OFF).
CAUTION:
- Do not keep the auxiliary/12V Starter Battery removed for a long period of time (approximately 1 month or more). (The BMU will not be able to comprehend the traction/Main Drive Lithium-ion battery status.)
- If the auxiliary/12V Stater Battery has necessarily been removed for a long period of time (approximately 1 month or more), perform "BMU Learning Value Manual Writing." (Refer to PRECAUTIONS BEFORE SERVICE - PROCEDURES FOR WRITING BMU LEARNING VALUE .)