Diagnostic Procedure
WARNING: This page is about a different variant/trim than selected.
- STEP 1. Scan tool data list
- Item 52: Select switch (up)
- Item 53: Select switch (down)
(Refer to DATA LIST REFERENCE TABLE .)
Q: Is the check result normal?
- YES: Intermittent malfunction
- NO: Go to Step 2.
- STEP 2. Shift switch assembly single unit check
Refer to SHIFT SWITCH ASSEMBLY CONTINUITY CHECK .
Q: Is the check result normal?
- YES: Go to Step 3.
- NO: Replace the selector lever assembly.
- STEP 3. Check the following connector:
- C-130 TCM connector
- C-127 Intermediate connector
- C-20 Selector lever assembly connector
- C-01 Grounding connector
- C-108 Joint connector (4)
Check the terminals for a contact status problem and internal short circuit.
Q: Is the check result normal?
- YES: Go to Step 4.
- NO: Repair the connector concerned.
- STEP 4. Check for open circuit and short to ground in the wiring harness between the selector lever assembly connector and the TCM connector.
- Between C-20 selector lever assembly connector (terminal No.6) and body ground
- Between C-20 selector lever assembly connector (terminal No.8) and C-130 TCM connector (terminal No.35)
- Between C-20 selector lever assembly connector (terminal No.9) and C-130 TCM connector (terminal No.44)
- Between C-20 selector lever assembly connector (terminal No.10) and C-130 TCM connector (terminal No.43)
Q: Is the check result normal?
- YES: Go to Step 5.
- NO: Repair the wiring harness.
- STEP 5. Retest the system.
Q: Does the malfunction take place again?
- YES: Replace TCM.
- NO: Intermittent malfunction