Inspection Procedure 1: Power Supply Circuit Check; Inspection Procedure 2: The Odometer And The Trip Meter Are Not Displayed.; Inspection Procedure 3: No Needle Meters Work.; Inspection Procedure 4: If The Ignition Switch Is Turned To The On Position, The Indicator And Warning Lights Do Not Illuminate Normally: Diagnosis
WARNING: This page is about a different car, the 2014 Mitsubishi Outlander. However, it is still accessible from the selected car via links, so may be relevant.
Required Special Tools:
- MB991223: Harness Set
- MB992006: Extra Fine Probe
- STEP 1. Using scan tool (M.U.T.-III), read the combination meter diagnostic trouble code
Check if DTC is stored in the combination meter.
CAUTION: To prevent damage to scan tool (M.U.T.-III), always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting scan tool (M.U.T.-III).- Connect scan tool (M.U.T.-III). Refer to "HOW TO CONNECT THE SCAN TOOL (M.U.T.-III) ."
- Turn the ignition switch from "LOCK" (OFF) position to "ON" position.
- Check if DTC is stored.
- Turn the ignition switch to the "LOCK" (OFF) position.
Q: Is the DTC stored?
- YES: Troubleshoot the combination meter (Refer to COMBINATION METERS DIAGNOSTIC ).
- NO: Go to Step 2.
- STEP 2. Voltage measurement at the combination meter connector
- Disconnect the connector, and measure at the wiring harness side.
- Turn the ignition switch to the LOCK (OFF) position.
- Measure the voltage between the combination meter connector (B+B terminal) and ground.
OK: The voltage should measure approximately 12 volts (battery positive voltage).
Q: Is the check result normal?
- YES: Go to Step 4.
- NO: Go to Step 3.
- STEP 3. Check of open circuit in B+B line between the fusible link and combination meter connector.
Q: Is the check result normal?
- YES: The trouble can be an intermittent malfunction (Refer to HOW TO COPE WITH INTERMITTENT MALFUNCTION ).
- NO: Repair the connector(s) or wiring harness.
- STEP 4. Voltage measurement at the combination meter connector
- Disconnect the connector, and measure at the wiring harness side.
- Turn the ignition switch to the ON position.
- Measure the voltage between the combination meter connector (IG1 terminal) and ground.
OK: The voltage should measure approximately 12 volts (battery positive voltage).
Q: Is the check result normal?
- YES: Go to Step 7.
- NO: Go to Step 5.
- STEP 5. Using scan tool (M.U.T.-III), check data list
Check the input signal from the ignition switch (IG1) in the ETACS-ECU.
- Turn the ignition switch to the ON position.
Item No. Item name Normal condition Item 254 IG voltage Battery positive voltage OK: Normal condition is displayed.
Q: Is the check result normal?
- YES: Go to Step 6.
- NO: Troubleshoot the ETACS-ECU. Refer to INSPECTION PROCEDURE 2: THE IGNITION SWITCH (IG1) SIGNAL IS NOT RECEIVED .
- Turn the ignition switch to the ON position.
- STEP 6. Check of open circuit in IG1 line between the ignition switch (IG1) and combination meter connector.
Q: Is the check result normal?
- YES: The trouble can be an intermittent malfunction (Refer to HOW TO COPE WITH INTERMITTENT MALFUNCTION ).
- NO: Repair the connector(s) or wiring harness.
- STEP 7. Resistance measurement at the combination meter connector
- Disconnect the connector, and measure at the wiring harness side.
- Measure the resistance between the combination meter connector (GND terminal) and ground.
OK: The resistance should be 2 ohms or less
Q: Is the check result normal?
- YES: Go to Step 9.
- NO: Go to Step 8.
- STEP 8. Check of open circuit in GND line between combination meter connector and ground.
Q: Is the check result normal?
- YES: The trouble can be an intermittent malfunction (Refer to HOW TO COPE WITH INTERMITTENT MALFUNCTION ).
- NO: Repair the connector(s) or wiring harness.
- STEP 9. Retest the system
Q: Is the check result normal?
- YES: The trouble can be an intermittent malfunction (Refer to HOW TO COPE WITH INTERMITTENT MALFUNCTION ).
- NO: Replace the combination meter.