Diagnostic Procedure
- STEP 1. Check other diagnostic trouble codes.
Q: Are other diagnostic trouble codes stored?
- YES: Go to the appropriate troubleshooting.
- NO: Go to Step 2.
- STEP 2. Check the following connector:
- B-08 CVT assembly connector
- C-40 TCM connector
- A-09 Intermediate connector
Check contacts for internal short circuit.
Q: Is the check result normal?
- YES: Go to Step 3.
- NO: Repair the defective connector.
- STEP 3. Check for short to ground in the wiring harness between the TCM connector and the CVT assembly connector.
- Between C-40 TCM connector (terminal No. 39) and B-08 CVT assembly connector (terminal No. 7)
OK: 100 Ω or more
Q: Is the check result normal?
- YES: Go to Step 4.
- NO: Repair the wiring harness.
- Between C-40 TCM connector (terminal No. 39) and B-08 CVT assembly connector (terminal No. 7)
- STEP 4. Symptom recheck after erasing diagnostic trouble code
Q: Is the check result normal?
- YES: Intermittent malfunction
- NO: Replace the TCM, and then go to Step 5.
- STEP 5. Retest the system.
Q: Is the check result normal?
- YES: The procedure is complete.
- NO: Replace the CVT assembly.